Heater Break Protection Temperature Controller

Heater Break Protection Temperature Controller

Heater Break Protection Temperature Controller is a single-loop temperature process control instrument and display instrument based on microprocessor technology. It can control and display process parameters such as temperature, pressure, and flow. Heater Break Protection Temperature Controller flexible settings, convenient configuration, and simple operation.
Send Inquiry
Description

Heater Break Protection Temperature Controller is a single-loop temperature process control instrument and display instrument based on microprocessor technology. It can control and display process parameters such as temperature, pressure, and flow. Heater Break Protection Temperature Controller flexible settings, convenient configuration, and simple operation.

 

Features

 

 

Universal input: Accepts thermal resistors, thermocouples and DC signals, compatible with 29 types of industrial input signals
Modular design: Output can be freely configured
Universal power supply: 100-240V AC, 50Hz
Multiple alarms
Alarm status indicator lights
Multiple control modes: ON/OFF and PID
Photoelectrically isolated RS-485 communication interface

 

01/

Inputs
Thermocouples: K, S, R, T, E, J, B, N, WRe3-WRe25, WRe5-WRe26
Thermal resistors: Cu50, PT100
Resistance signals: 0~80Ω, 0~400Ω
Current signals: 0~10mA, 0~20mA, 4~20mA
Voltage/millivolt signals: 0~20mV, 0~100mV, -20~+20mV, -100~+100mV, 0~1V, 0~2V, 0~5V, 1~5V, 0~10V, 2~10V, -5V~+5V, -10V~+10V

02/

Outputs
Main control output:
0 - Linear output
1 - Relay
2 - Transistor
3 - Thyristor
Linear signals:
0 - (4-20mA)
1 - (0-10mA)
2 - (0-20mA)
Supports 2 output channels

03/

Communication

Photoelectrically isolated RS-485 communication interface

04/

Alarm

2 channels of relay alarms

 

Other Detailed Parameters

 
Input signal range 29 common industrial standard signals
Basic error 0.002FS±1 digit
Measurement AD 20-bit, 13SPS
Output DA 12-bit, 100KSPS
Main control output 1 channel
Alarm output 2 channels (Model 2216 has 1 alarm channel)
Input impedance ≥500KΩ for voltage, ≤300Ω for current (with external 250Ω resistor in parallel), ≤0.25mA for thermal resistors, ≥500KΩ for thermocouples
Output impedance (load capacity) ≤500Ω for current (can be 650Ω for special current requirements, please specify when ordering), relay
Display method Nixie tube
Sampling period 0.1S (average)
Communication protocol MODBUS RTU (RS485 interface, 2-wire system)
Transmission distance 1200 meters
Parity check None, odd, even
Baud rate 4800, 9600, 19200
Communication data format 1 start bit, 8 data bits, 1 stop bit
Power supply voltage AC220V
Isolation voltage Isolation between input, output and power supply, 2000V AC for 1 minute
Operating conditions Temperature: -20℃~+50℃, Humidity:0.1-0.9RH
Storage conditions Temperature: -40℃~+80℃, Humidity:0.1-0.9RHModel Selection & Dimensions
DK2208 48×96mm
Cutout Dimension DK2208: 44×92mm

 

Hot Tags: heater break protection temperature controller, China heater break protection temperature controller manufacturers, suppliers, factory, 4 Channel 485 Data Acquisition Instrument, DIN Rail Mounted Temperature Controller, Dual Loop Controller for Humidity Temperature, Dual MODBUS Communication Temperature Controller, Group PID Precise Temperature Controller, Intelligent Temperature Controller Supports MODBUS RTU