It integrates power regulation and voltage regulation functions. Adopting imported components and high-precision digital circuit control, single-phase 50A dual-communication SCR controller features longer service life, safety and reliability. Equipped with a digital display, it enables more convenient on-site modification of control parameters.single-phase 50A dual-communication SCR controller supports multiple input signals and is equipped with soft start and soft stop functions. Optional features include 2-channel Modbus RTU communication, true RMS voltage/current display, and DA analog output function; single-phase models come standard with 2-channel DO (Digital Output).
single-phase 50A dual-communication SCR controller is widely used in scenarios such as lighting adjustment in stages and KTVs, speed regulation of single-phase motors, and heating power control.
Features
Intelligent integrated technology of voltage and power regulation, integrating variable-cycle and fixed-cycle zero-crossing control.
PLC transistor output can directly drive and control the device.
Intelligent dual-Modbus online distribution control.
True RMS voltage, current, and power measurement and transmission functions.
Signal Control Methods
Automatic Control: Standard signal inputs including 4-20mA, 0-10mA, 0-5V, 0-10V, 1-5V, 2-10V, and PWM.
Manual Control: 10K potentiometer adjustment; panel button adjustment.
Control Method
Integrated technology of voltage regulation phase-shifting and zero-crossing cycle power regulation, capable of realizing closed-loop control such as constant current, constant voltage, and constant power.
Load
Applicable Load Types
Various pure resistive loads, various inductive loads, IR infrared lamps, and other loads; various DC power supplies, electrolysis power supplies, and electroplating power supplies.
Load Voltage
110V, 220V, 380V, 440V, 690V, etc.
Control Voltage
100~245V self-adaptive voltage.
Load Frequency
50Hz/60Hz.
Soft Start/Soft Stop
Configurable range: 0-400 seconds.
01
Protection System
Electronic overvoltage and overcurrent protection; overtemperature protection.
Built-in fast-acting fuse.
02
Analog Output Signals
Voltage signals: 0-10V, 0-5V, 2-10V, 1-5V
Current signals: 0-20mA, 4-20mA
03
DO Output Signals
2 channels.
Alarm Output Signals
Normally open (NO) and normally closed (NC).
04
Communication
Optional 2-channel standard MODBUS RTU communication.
Cooling Method
Air cooling.
05
Other Detailed Parameters
| Input Impedance | 120Ω (for 4-20mA input mode) |
| Soft Start Time Range | Adjustable range of 0-400 seconds |
| Output Voltage Control Range | 0.0-0.98 of the input voltage |
| Adjustment Output Resolution | 0.2° |
| Protection Action Time | < 20ms |
| Relay Contact Rating | 250V AC 2A |
| External Voltage Control Function | Voltage adjustment (internal) / 0.00-1.00 |
| Insulation Resistance | 20 MΩ (at 500V DC) |
| Dielectric Strength | 2000V AC for 1 minute (for 220V models); 2500V AC for 1 minute (for 380V models) |
| Current Limiting Function | Adjustment range of 0.20-1.10 |
| Overcurrent Protection System | Electronic-type protection;Schematic Diagram for Model Selection & Dimensions |
| Length × Width × Height | 155mm × 81mm × 131mm |
Hot Tags: single-phase 50a dual-communication scr controller, China single-phase 50a dual-communication scr controller manufacturers, suppliers, factory, Ethernet Communication Controllable Silicon Power Controller, High Energy Efficiency Three Phase Power Regulator, Single phase 50A Dual communication SCR Controller, Three Phase Two Control Industrial Thyristor Controller, Three phase Two wire Thyristor Power Regulator, Zero crossing Power Control Device