3PH DIN Rail Mounting Multifunctional Meter adopt RMS (Root Mean Square) measurement for three-phase voltage, three-phase current, three-phase active power, combined active power, and line voltage frequency.
Featuring high accuracy, imported chips, and stable quality, the meters support the following functions:
2-channel relay alarm;
3-channel transmission output;
Communication function;
DIN rail mounting for easier installation.
3PH DIN Rail Mounting Multifunctional Meter Features
Digital filtering to eliminate interference and prevent non-critical value jumping;
Supports 2-channel relay alarm;
3-channel transmission output;
Communication function;
RMS (Root Mean Square) measurement for three-phase voltage, three-phase current, three-phase active power, combined active power, and line voltage frequency;
35mm standard DIN rail mounting.
Input
Voltage-compatible input: 0-400V; extended range: 0-50KV (voltage transformer required); voltage transformation ratio can be set arbitrarily;
Current-compatible input: 0-5A; extended range: 0-9999A (current transformer required); current transformation ratio can be set arbitrarily.
Output
4-20mA, 1-5V, 0-20mA, 0-10mA, 0-10V, 0-5V
Communication
Optically isolated RS-485 communication interface
Alarm
2-channel relay alarm
Other Detailed Parameters
| Parameter | Specification |
| Measurement Accuracy | ±0.005 (±0.003) |
| Response Frequency | 40Hz~70Hz |
| Display Range | 0.000-9999-99.99 |
| Operating Power Supply | AC 85~260V, 3W |
| Operating Environment | 0~+50℃; ≤85% RH |
| Relay Contact Capacity | AC 220V/5A |
| Relay Contact Lifespan | 100,000 operations |
| Transmission Output Accuracy | 16-bit, ±0.002 |
| Model Selection & Dimensions | Mounting: 35mm standard DIN rail mounting Dimensions: 90×75×104.5mm |
| Model Selection Example | Example: A user needs to measure (three-phase three-wire system) three-phase AC voltage (0~380V), rated current (50A), three-phase current, and power. The requirements are as follows: upper-limit alarm when the measured voltage is higher than 400V, lower-limit alarm when the measured voltage is lower than 300V, AC 220V system power supply; transmit the three-phase voltage average (0~380V), three-phase current average (0~50A), and total active power (0~40kW) as 0-5V, 4-20mA, and 0-20mA outputs respectively; and transmit data to the upper computer. DIN rail mounting is required. Selected instrument model: DK64DN-R-R-0V5-4MA20-0MA20-S |
Hot Tags: 3ph din rail mounting multifunctional meter, China 3ph din rail mounting multifunctional meter manufacturers, suppliers, factory, True RMS Multifunctional Meter with Communication, 3PH True RMS Multifunctional Power Meter, True RMS Measurement Voltage and Current Meter, multifunctional power meters, Multifunctional Power Meter with Expandable Range, Intelligent Voltage and Current Meter