24-bit high-speed multi-channel synchronous data acquisition, with full 5-digit data display capable of showing ±10000.
Dual MODBUS RTU communication, with optional MODBUS TCP Ethernet. It supports the communication data synchronization function, enabling automatic SV (Set Value) synchronization during multi-instrument operation and realizing synchronized data control of multiple control instruments.
Oxygen Sensor Input Carbon Potential Controller can implement communication-based digital PID control, directly controlling one or multiple digital power control instruments to achieve full digital control.
Communication data supports the 16-bit integer standard. When the data exceeds 16 bits, it can automatically switch to 32-bit integer data reading and writing, realizing high-precision, full-resolution real reading for process control.
Equipped with a 32-bit RISC instruction set industrial-grade microprocessor, it features higher anti-interference capability and faster response speed.
The control output refresh rate is 50ms, adapting to faster control processes.
The dual-channel mathematical calculation function enables the implementation of complex algorithm logic, and the instrument is equipped with high-precision carbon potential measurement and control functions.
Oxygen Sensor Input Carbon Potential Controller has 4 channels of hard-contact alarm output and program control output, as well as 9 channels of programmable DIO (Digital Input/Output) functions-each IO can be customized as input or output according to requirements.
Oxygen Sensor Input Carbon Potential Controller supports dual-sensor high-low temperature switching function and redundancy switching function. When a sensor malfunctions, it automatically switches to the backup input measurement channel.
Program curves can control the arbitrary timed output of 9 channels. It integrates the fixed time-scale function output mode and the program curve time-scale function, allowing flexible configuration as needed. It also supports rate curve mode and classic time-mode curve input functions.
Full-screen OVERVIEW display technology enables real-time insight into each process control parameter.
It supports 20 curves, with 50 segments per curve, and allows in-segment cycling and program curve cycling.
10 groups of grouped PID and 10 groups of grouped output limiting control are available, meeting the requirements of various control working conditions.
It supports analog setting and digital remote setting functions.
It supports non-standard signal input and multi-point linearization processing, as well as input of 47 types of industrial standard sensor signals.
Features
True-color IPS TFT wide-viewing-angle LCD display, full 5-digit, with innovative OVERVIEW color-changing display technology
Dual-port online communication control and industrial Ethernet, integrated with master station communication PID control
Supports 20 process curves (50 segments per curve), with in-segment cycling and curve cycling functions
Supports rate-mode curves and time-mode curves
10 groups of grouped PID and grouped output limiting function, suitable for loads with various characteristics
Supports analog remote setting, digital long-distance remote setting, and heater wire break alarm function
47 types of input signals, supporting PT1000 input and industrial oxygen probe carbon potential control
Adopts improved DK PID algorithm, supporting PV differentiation and derivative-first control
Innovatively designed with high-speed data acquisition and Class 0.1 measurement & control accuracy
Supports dual-sensor high-low temperature switching function and user-defined 8-point input curve correction function
Programmable DI (Digital Input) and DO (Digital Output) with customizable input/output functions
Input
Supports input of 47 types of industrial signals:
K, S, R, T, E, J, B, N, WRe3-WRe25, WRe5-WRe26, Cu50, Pt100, Pt500, Pt1000, 0~80Ω, 0~400Ω, 0~4000Ω, 0~10mA, 0~20mA, 4~20mA, 0~20mV, 0~100mV, -20~+20mV, -100~+100mV, 0~1V, 0~2V, 0~5V, 1~5V, 0~10V, 2~10V, -5V~+5V, -10V~+10V, Cu10, Cu100, Pt10, Pt50, Pt200, JPT10, JPT50, JPT100, JPT200, JPT500, JPT1000, Ni100, Ni200, Ni500, Ni1000
Output
Main Control Output:
4-20mA, 0-20mA, 0-10mA, Relay Output, Transistor Solid-State Output, Thyristor Output
Transmission Output:
4-20mA, 0-20mA, 0-10mA
Communication:
Supports dual communication
Standard Modbus RTU communication protocol
Standard Modbus TCP communication protocol
Alarm:
Supports 4-channel relay alarm output
Detailed Parameters
| Control Cycle | 50mS/100mS |
| Measurement Accuracy | 0.001FS (using 24-bit AD) |
| Sampling Rate | 20Hz/10Hz |
| Control Output | |
| Analog Signals | 12 BIT (True DA) – 4-20mA, 0-20mA, 0-10mA, 0-10V, 2-10V, 0-5V, 1-5V |
| Relay | 2A (250V AC) |
| Solid-State Relay (Transistor) | 22V 20mA |
| Thyristor | 3A 250V AC |
| Display Method | IPS TFT True-Color LCD |
| Signal Measurement Input Impedance |
≥500KΩ for voltage signals (≥100KΩ for 5V, 10V), ≤120Ω for current signals, ≥500KΩ for thermocouples Resistance measurement adopts a 3-wire system; the resistance of each signal transmission wire shall not exceed 10Ω |
| 8.1 Communication | Standard MODBUS RTU protocol (2-wire RS485) |
| Parity Check | None, Odd, Even |
| Communication Speed | 4800BPS, 9600BPS, 19200BPS, 38400BPS, 57600BPS |
| Communication Address Range | 1~247 |
| 8.2 Communication | Standard MODBUS TCP protocol |
| Communication Address | 0-255 |
| Subnet Mask | 0-255 |
| Gateway | 0-255 |
| Power Supply | 86~260V AC (47~63HZ) |
| Isolation Voltage | 2300V AC for 1 minute (isolation between input, output, and power supply) |
| Operating Temperature | 0~50℃ |
| Storage Conditions | Temperature -40℃~80℃; Humidity 0.1-0.9 (Relative Humidity) |
| External Dimensions | 48×96×130mm (mounting hole size |
| EMC Standard | EN61326* |
| Executive Standard | IEC60950-1 |
| Protection Class | IP66 |
| Power Consumption | 12W |
| DI and DO |
The DIO function is programmable and can be defined as input (DI) or output (DO) via parameter settings. DI can only accept passive dry contact input signals. DO is an open-collector output with a load capacity of up to 200mA; an external 24V signal is required to drive intermediate relays. |
Hot Tags: oxygen sensor input carbon potential controller, China oxygen sensor input carbon potential controller manufacturers, suppliers, factory, 8 Segment Curve Controller for Humidity and Temperature, Dual Loop DIN Rail Temperature Controller, Furnace Carbon Potential Controller, Group PID Control Temperature Controller, Intelligent Temperature Controller Supports MODBUS RTU, JT16DN Series High Precision Temperature Process Control Instruments

