4-Channel Universal Input Modbus Module

4-Channel Universal Input Modbus Module

4-Channel Universal Input Modbus Module is a four-channel input analog analog analog input acquisition module with four input signals, where each channel can accept different input signals. 4-Channel Universal Input Modbus Module features one DA function (which can be switched between communication-controlled DA or transmission function). Internally, it adopts a 20-bit high-precision measurement AD.4-Channel Universal Input Modbus Module is equipped with a liquid crystal display to show the values of each channel.
Description

4-Channel Universal Input Modbus Module is a four-channel input analog analog analog input acquisition module with four input signals, where each channel can accept different input signals. 4-Channel Universal Input Modbus Module features one DA function (which can be switched between communication-controlled DA or transmission function). Internally, it adopts a 20-bit high-precision measurement AD.4-Channel Universal Input Modbus Module is equipped with a liquid crystal display to show the values of each channel.

 

Features

 

 

4-Channel Universal Input Modbus Module is an intelligent module integrating signal acquisition, transmission, and DA output. It can measure 24 types of common industrial standard signals across 4 channels and adopts the standard two-wire ModBus RTU communication method. This module is widely used in various industrial measurement and control systems.

It is a digital intelligent data acquisition and transmission module that adopts electronic technology, with a high-speed signal processor and microprocessor as its core.

It can measure 24 types of common industrial standard signals independently across 4 channels. It can either select 1 out of the 4 channels to transmit and output the signal to a remote end, or be set via parameters to serve as a communication-based remote given DA.

It is equipped with a photoelectrically isolated RS-485 communication interface and adopts the ModBus RTU communication protocol. The circuit design features three-terminal isolation for input, power supply, and output.

 

01/

Inputs

K-type thermocouple; S-type thermocouple;

R-type thermocouple; T-type thermocouple;

E-type thermocouple; J-type thermocouple;

B-type thermocouple; N-type thermocouple;

WRe3-WRe25 thermocouple; WRe5-WRe26 thermocouple; 4~20mA current signal;

0~20mA current signal; Cu50 copper resistor;

PT100 platinum resistor; 0~80Ω resistance signal;

0~400Ω resistance signal; 0~20mV voltage signal;

0~100mV voltage signal; 0~1V voltage signal;

1~5V voltage signal; 0~5V voltage signal;

-20~+20mV voltage signal; -100~+100mV voltage signal; -5V~+5V voltage signal

02/

Output

Channel 0: 0-5V / 0-20mA / 0-10mA

Channel 1: 1-5V / 4-20mA

Communication

Photoelectrically isolated MODBUS RTU communication

Alarm

None

 

Other Detailed Parameters

 

 

Parameter Category Specification Details
Number of Input Channels 4 independent channels, supporting different input types
Input Signal Range 24 types of common industrial standard signals
A/D Conversion Resolution 18 BIT
A/D Conversion Time 13 SPS (Samples Per Second)
D/A Conversion Resolution 16 BIT
D/A Conversion Time 10M SPS (Mega Samples Per Second)
Communication Method RS485 interface, two-wire system
Driving Distance 1200 meters
Communication Baud Rate 4800, 9600, 19200 bps
Communication Data Format 1 start bit, 8 data bits, 1 stop bit
Communication Protocol MODBUS RTU
Power Supply Voltage DC24V ± 0.1V
Isolation Voltage 2000V AC


Model Selection Dimensions
Overall Dimensions: 88mm × 72mm × 59mm
Mounting: 35mm DIN rail mounting
Model Selection Examples
DK5041-IN1:X(Y-Y)-IN2:X(Y-Y)-IN3:X(Y-Y)-IN4:X(Y-Y)-OUT:X(Y-Y)-DA:X

 

Explanation of Model Code:
DK5041: Product model.
IN1:X(Y-Y): "IN1" indicates Channel 1 input; "X" represents the input signal type; "Y-Y" in parentheses denotes the input signal range.
IN2:X(Y-Y): "IN2" indicates Channel 2 input; "X" represents the input signal type; "Y-Y" in parentheses denotes the input signal range.
IN3:X(Y-Y): "IN3" indicates Channel 3 input; "X" represents the input signal type; "Y-Y" in parentheses denotes the input signal range.
IN4:X(Y-Y): "IN4" indicates Channel 4 input; "X" represents the input signal type; "Y-Y" in parentheses denotes the input signal range.
OUT:X(Y-Y): "X" is selected from 1 to 5 (1-4 correspond to the transmitted channel values, and 5 is used as communication-given DA); "(Y-Y)" denotes the corresponding transmission range. When used as remote communication-given, it adopts the default 16-bit communication-given value (0-65535).
DA:X: "DA" indicates DA transmission output; "X" represents the corresponding output signal type (e.g., 4-20mA is written as "4MA20").

Example:
A customer needs to measure:
1 channel of K-type thermocouple signal,
1 channel of 20mV pressure sensor signal (0-2000 Pa),
1 channel of 4-20mA signal (0-5000),
1 channel of 0-5V signal (0-8000),
and use DA for communication-given control (output signal: 4-20mA).
The selected model code is:
DK5041-IN1:K-IN2:0MV20(0-2000)-IN3:4MA20(0-5000)-IN4:0V5(0-8000)-OUT:5-DA:4MA20
 

Hot Tags: 4-channel universal input modbus module, China 4-channel universal input modbus module manufacturers, suppliers, factory, Switching Pulse Counting Acquisition and Transmission Module, True RMS Measurement Power Collection Module, Dual Mode DA Output 485 Acquisition Module, Frequency Measurement Counting Acquisition Module, 8 Channel Analog Input 485 Module, Universal Input RTU Acquisition Module